Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number SYS2361, which is a Powersupply item from Atc Power Systems Inc that is listed with the NSN 6130-01-252-2067 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number SYS2361 was specifically produced by Atc Power Systems Inc under the CAGE Code 61814, providing traceability. Furthermore, with the NSN 6130-01-252-2067, one can also determine that this listing falls under Federal Supply Class (FSC) 6130 Converters Electrical Non Rotating. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number SYS2361, and we will be in touch.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-252-2067 Item PartTypeName: POWER SUPPLY | 6130 | 012522067 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
134053-01 | 5 | 9 | 7 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 11.500 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.400 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 6.000 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
AMQY | INSTALLATION DESIGN | PANEL |
ANPM | INPUT PHASE | THREE SINGLE OPERATING POWER RQMT |
ANRQ | FREQUENCY REGULATION PERCENT | 2.0 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
APNX | INPUT VOLTAGE RATING | 175.0 AC POUNDS PER HOUR DRY SINGLE OPERATING POWER RQMT AND 225.0 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 5.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/50.0 DEG CELSIUS |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
CWGH | OUTPUT CURRENT RATING | 10.0 DC AMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 3.0 DC AMPERES NOMINAL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 12 MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
CWHJ | OUTPUT CONNECTION TYPE | SCREW MULTIPLE POWER OUTPUTS W/IDENTICAL RATINGS |
CWHQ | INPUT CONNECTION TYPE | SCREW SINGLE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 4 SINGLE OPERATING POWER RQMT |
CWKG | VENTILATION DESIGN TYPE | AIR COOLED |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.