Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number 930C513PT1, which is a Transformer Power item from Bae Systems Controls Inc that is listed with the NSN 5950-00-102-5931 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number 930C513PT1 was specifically produced by Bae Systems Controls Inc under the CAGE Code 89954, providing traceability. Furthermore, with the NSN 5950-00-102-5931, one can also determine that this listing falls under Federal Supply Class (FSC) 5950 Coils and Transformers. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number 930C513PT1, and we will be in touch.
MRC | Criteria | Characteristic |
---|---|---|
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.630 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 2.380 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
CQLC | (NON-CORE DATA) WINDING TAP LOCATION | CENTER TAP CENTER TAP |
CRMJ | WINDING POWER RATING | 15.0 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY 2.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY 3.5 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 10 WIRE LEAD |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 50.00 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY 100.00 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY 10.00 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CMLP | THREAD QUANTITY PER INCH | 32 SINGLE GROUP |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAU | BODY HEIGHT | 2.060 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.760 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ADAT | BODY WIDTH | 2.120 INCHES NOMINAL |
TEST | TEST DATA DOCUMENT | 89954-930C513PT1 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING D |