Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number 5703646-503, which is a Circuit Breaker item from C Systems Llc that is listed with the NSN 5925-00-988-7855 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number 5703646-503 was specifically produced by C Systems Llc under the CAGE Code 088A2, providing traceability. Furthermore, with the NSN 5925-00-988-7855, one can also determine that this listing falls under Federal Supply Class (FSC) 5925 Circuit Breakers. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number 5703646-503, and we will be in touch.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-988-7855 Item Description: NO ITEM NAME AVAILABLE | 5925 | 009887855 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5703646&503 | 1 | C |
MRC | Criteria | Characteristic |
---|---|---|
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.950 INCHES MAXIMUM |
ADAT | Body Width | 2.290 INCHES MAXIMUM |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.058 INCHES MINIMUM AND |
BBRJ | Special Handling Feature | MAGNETIC |
CQXF | Inclosure Protection Type For Which Designed | FUNGUS RESISTANT AND |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPLM | Maximum Continuous Load Current Rating Per Pole | 50.0 AMPERES AC ALL LOCATIONS |
PKWT | Unpackaged Unit Weight | 0.280 POUNDS |
AKPX | Pole Quantity | 3 |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.740 INCHES MINIMUM AND |
AJWX | Mounting Surface To Terminal End Distance | 2.620 INCHES MINIMUM AND |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.760 INCHES MAXIMUM |
AJEC | Boss Height | 0.140 INCHES MAXIMUM |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 115.0 ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AJEC | Boss Height | 0.120 INCHES MINIMUM AND |
CPRX | Actuator Position Designation | AT EACH POLE |
CPRT | Manual Actuator Type And Quantity | 3 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
AAJE | Thread Pitch Diameters | 0.1177 TO 0.1214 INCHES |
AXHR | Mounting Facility Type And Quantity | 6 THREADED HOLE |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
CQJX | Nominal Thread Size | 0.138 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 2.640 INCHES MAXIMUM |
THSD | Thread Series Designator | UNC |
ADAQ | Body Length | 2.565 INCHES MINIMUM AND |
ADAQ | Body Length | 2.595 INCHES MAXIMUM |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
TTQY | Terminal Type And Quantity | 6 THREADED STUD |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.930 INCHES MINIMUM AND |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.740 INCHES MINIMUM AND |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.760 INCHES MAXIMUM |
ADAT | Body Width | 2.270 INCHES MINIMUM AND |
CMLP | Thread Quantity Per Inch | 32 |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 0.200 MINIMUM AT 200 PCT AND |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 1.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRQ | Reset Method | MANUAL |
MRC | Decoded Requirement | Clear Text Reply |
CPRY | External Actuator Linkage Arrangement | ONE, TWO, AND THREE LINKED |
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.078 INCHES MAXIMUM |
CQXF | Inclosure Protection Type For Which Designed | MOISTURE RESISTANT |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.