Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number 87056, which is a Circuitbreaker item from Dla Land And Maritime that is listed with the NSN 5925-01-480-4125 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number 87056 was specifically produced by Dla Land And Maritime under the CAGE Code 16236, providing traceability. Furthermore, with the NSN 5925-01-480-4125, one can also determine that this listing falls under Federal Supply Class (FSC) 5925 Circuit Breakers. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number 87056, and we will be in touch.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-480-4125 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014804125 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
87056 | 5 | 9 | D |
MRC | Criteria | Characteristic |
---|---|---|
ZZZK | Specification/Standard Data | 14933-87056B GOVERNMENT SPECIFICATION |
CPLM | Maximum Continuous Load Current Rating Per Pole | 6.0 AMPERES DC ALL LOCATIONS |
ABXD | Bushing Length | 0.380 INCHES MAXIMUM |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 240.0 AC ALL LOCATIONS AND 50.0 DC ALL LOCATIONS |
CPRJ | Trip Release Method | THERMAL-MAGNETIC ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
AKPX | Pole Quantity | 2 |
CPRL | Trip Release Characteristic | TIME DELAY FIRST LOCATION |
CPRQ | Reset Method | MANUAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 135.0 FIRST LOCATION |
ADAT | Body Width | 1.281 INCHES MAXIMUM |
ADTV | Case Material | PLASTIC |
THSD | Thread Series Designator | UNEF |
TTQY | Terminal Type And Quantity | 4 WIRE HOOK |
CQJX | Nominal Thread Size | 0.375 INCHES |
AJWX | Mounting Surface To Terminal End Distance | 1.780 INCHES NOMINAL |
AAQL | Body Style | |
MRC | Decoded Requirement | Clear Text Reply |
ADAQ | Body Length | 1.562 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.875 INCHES NOMINAL |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.625 INCHES NOMINAL |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 245.0 AC ALL LOCATIONS AND 52.000 DC ALL LOCATIONS |
CMLP | Thread Quantity Per Inch | 32 |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.