Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number S121-0174, which is a Relay Electromagnetic item from Engineered Electric Company that is listed with the NSN 5945-00-392-6434 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number S121-0174 was specifically produced by Engineered Electric Company under the CAGE Code 93742, providing traceability. Furthermore, with the NSN 5945-00-392-6434, one can also determine that this listing falls under Federal Supply Class (FSC) 5945 Relays and Solenoids. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number S121-0174, and we will be in touch.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-392-6434 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 003926434 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
13C35D32-0014 | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 1.406 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.187 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.406 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | DUST TIGHT |
AGAV | END ITEM IDENTIFICATION | ENGINE GENERATOR (EG) 37.5,KVA,FREMONT DIVISION |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 450.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 71.0 MILLIAMPERES DC SINGLE WINDING |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 32.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC |
FEAT | SPECIAL FEATURES | RELAY PLUG IN; REFERENCE DATA: ITEM 53,OSR,OTR,OCR,OPR,OPX,CDR,BOX TI 6980-32,FREMONT AUTOMATIC DIESEL ENGINE DRIVEN ELECTRIC GENERATOR SET,MODEL J510-1,BK 28,CHP 1-16,PG VIII-7 |
TTQY | TERMINAL TYPE AND QUANTITY | 2 STANDARD TUBE BASE ENERGIZING ELEMENT |
TTQY | TERMINAL TYPE AND QUANTITY | 6 STANDARD TUBE BASE CONTACTS |