Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number 5925PL1598684, which is a Circuitbreaker item from Inspektorat Wsparcia Sil Zbrojnych that is listed with the NSN 5925-01-473-0646 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number 5925PL1598684 was specifically produced by Inspektorat Wsparcia Sil Zbrojnych under the CAGE Code 9009H, providing traceability. Furthermore, with the NSN 5925-01-473-0646, one can also determine that this listing falls under Federal Supply Class (FSC) 5925 Circuit Breakers. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number 5925PL1598684, and we will be in touch.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-473-0646 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014730646 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
3126509 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
MRC | Decoded Requirement | Clear Text Reply |
AKPX | Pole Quantity | 2 |
CPLM | Maximum Continuous Load Current Rating Per Pole | 20.0 AMPERES DC ALL LOCATIONS |
ABMK | Overall Width | 0.820 INCHES NOMINAL |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 36.0 DC ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 2 BUS BAR |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 20.0 DC ALL LOCATIONS |
ABKW | Overall Height | 0.390 INCHES NOMINAL |
CPRL | Trip Release Characteristic | INSTANTANEOUS SINGLE LOCATION |
CPRQ | Reset Method | AUTOMATIC |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 100.0 ALL LOCATIONS |
CRCF | Trip Release Ambient Temp Rating | 40.0 DEG CELSIUS NOMINAL SINGLE LOCATION |
CPRP | Ultimate Trip Time Per Pole In Seconds | 15.000 NOMINAL ALL LOCATIONS |
ADTV | Case Material | PLASTIC |
AGAV | End Item Identification | 2320-01-465-2174 |
AXHR | Mounting Facility Type And Quantity | 2 SLOT |
CXCY | Part Name Assigned By Controlling Agency | CIRCUIT BREAKER, 20 AMP |
ABHP | Overall Length | 1.350 INCHES NOMINAL |
CPRJ | Trip Release Method | THERMAL SINGLE LOCATION |
FEAT | Special Features | USED ON MK23,MK25,MK27,MK28,MK29,MK30 |
AAQL | Body Style | RECTANGULAR DIMENSIONAL ENVELOPE |
CPSM | Internal Trip Release Configuration | RELAY TRIP SINGLE LOCATION |
ABTD | Mounting Slot Width | 0.210 INCHES NOMINAL |