Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number 223C38A, which is a Relay Electromagnetic item from Kurman Relays Inc that is listed with the NSN 5945-00-259-6551 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number 223C38A was specifically produced by Kurman Relays Inc under the CAGE Code 55496, providing traceability. Furthermore, with the NSN 5945-00-259-6551, one can also determine that this listing falls under Federal Supply Class (FSC) 5945 Relays and Solenoids. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number 223C38A, and we will be in touch.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-259-6551 Item PartTypeName: RELAY,ELECTROMAGNETIC | 5945 | 002596551 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
223C38A | 2 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.620 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 1.560 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 2.620 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.180 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 1.95 KILOHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 3 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | TRIANGLE SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 2.5 MILLIAMPERES DC SINGLE WINDING |
CSQJ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE | 2.125 INCHES NOMINAL SINGLE MOUNTING FACILITY |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 2.0 AMPERES AC RESISTIVE LOAD AND 250.0 MILLIAMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 110.0 AC AND 110.0 DC |
FEAT | SPECIAL FEATURES | TROPICALIZED |
TTQY | TERMINAL TYPE AND QUANTITY | 5 PIN ALL FUNCTIONS |