Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number 8500-005-3, which is a Circuitbreaker item from Labinal Llc that is listed with the NSN 5925-01-417-8690 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number 8500-005-3 was specifically produced by Labinal Llc under the CAGE Code 81640, providing traceability. Furthermore, with the NSN 5925-01-417-8690, one can also determine that this listing falls under Federal Supply Class (FSC) 5925 Circuit Breakers. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number 8500-005-3, and we will be in touch.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-417-8690 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014178690 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5D0001-3 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 1 |
AAQL | Body Style | SINGLE POLE TYPE |
CPLM | Maximum Continuous Load Current Rating Per Pole | 3.0 AMPERES AC SINGLE LOCATION AND 3.0 AMPERES DC SINGLE LOCATION |
CQXF | Inclosure Protection Type For Which Designed | GENERAL PURPOSE |
ABXD | Bushing Length | 0.175 INCHES MINIMUM |
FREQ | Frequency In Hertz | 400.0 SINGLE LOCATION |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC SINGLE LOCATION AND 28.0 DC SINGLE LOCATION |
CPRH | Circuit Protection Type | OVERCURRENT SINGLE LOCATION |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 800.0 AC SINGLE LOCATION |
CPRL | Trip Release Characteristic | TIME DELAY SINGLE LOCATION |
ADAT | Body Width | 0.700 INCHES NOMINAL |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 SINGLE LOCATION |
TTQY | Terminal Type And Quantity | 2 TAB W/SCREW |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | RESET |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT POLE ONE |
AXHR | Mounting Facility Type And Quantity | 1 THREADED BUSHING W/PANEL SEAL |
CPSM | Internal Trip Release Configuration | SERIES TRIP SINGLE LOCATION |
MRC | Decoded Requirement | Clear Text Reply |
ADAQ | Body Length | 0.780 INCHES MAXIMUM |
AJWX | Mounting Surface To Terminal End Distance | 1.852 INCHES MAXIMUM |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 0.700 INCHES NOMINAL |
CPRJ | Trip Release Method | MAGNETIC SINGLE LOCATION |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 3600.000 MINIMUM AT 115 PCT SINGLE LOCATION AND 20.000 MAXIMUM AT 200 PCT SINGLE LOCATION |
CPRT | Manual Actuator Type And Quantity | 1 PUSH-PULL |