Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number M1608, which is a Filter Radio Frequency Interfere item from Mtk Electronics Inc that is listed with the NSN 5915-01-119-2725 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number M1608 was specifically produced by Mtk Electronics Inc under the CAGE Code 59901, providing traceability. Furthermore, with the NSN 5915-01-119-2725, one can also determine that this listing falls under Federal Supply Class (FSC) 5915 Filters and Networks. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number M1608, and we will be in touch.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-119-2725 Item PartTypeName: FILTER,RADIO FREQUENCY INTERFERE | 5915 | 011192725 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
A-3874 | 6 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 181.6 MILLIMETERS NOMINAL |
ABKW | OVERALL HEIGHT | 97.0 MILLIMETERS NOMINAL |
ABTD | MOUNTING SLOT WIDTH | 6.35 MILLIMETERS NOMINAL |
ADAQ | BODY LENGTH | 150.0 MILLIMETERS NOMINAL |
ADAT | BODY WIDTH | 150.0 MILLIMETERS NOMINAL |
ADAU | BODY HEIGHT | 75.0 MILLIMETERS NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 130.0 MILLIMETERS NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0 TO 85.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 5TH RADIO INTERFERENCE 5TH FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 6TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 20.0 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 2ND RADIO INTERFERENCE 2ND FUNCTION |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 5.0 4TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 240.0 MILLIVOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 240.0 MILLIVOLTS DC 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 240.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 240.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 240.0 MILLIVOLTS DC 5TH RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 240.0 MILLIVOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 96906 |
AHBT | OUTPUT TERMINAL IDENTIFICATION | MS27468T17B35SA |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | ISO S |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR,RECEPTACLE OUTPUT 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 8 THREADED STUD INPUT 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 24.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 24.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 24.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 24.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 24.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 24.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 100.0 VOLTS AT SEA LEVEL |
CRST | BODY SURFACE TREATMENT | TIN |
FEAT | SPECIAL FEATURES | 8 FUNCTIONS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote