Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number 9451640-10, which is a Cable Assembly Specificationial Purpose E item from Ogden Air Logistics Center that is listed with the NSN 6150-01-483-8271 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number 9451640-10 was specifically produced by Ogden Air Logistics Center under the CAGE Code 98747, providing traceability. Furthermore, with the NSN 6150-01-483-8271, one can also determine that this listing falls under Federal Supply Class (FSC) 6150 Miscellaneous Electric Power and Distribution Equipment. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number 9451640-10, and we will be in touch.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6150-01-483-8271 Item PartTypeName: CABLE ASSEMBLY,SPECIAL PURPOSE,E | 6150 | 014838271 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
9451640-10 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AGAV | END ITEM IDENTIFICATION | NEXT ASSEMBLY P/N 9451502; USED ON: REENTRY SYSTEM TEST SET (RSTS) |
AKRZ | TERMINATION TYPE | CONNECTOR ALL ENDS ALL CONDUCTORS |
AMQN | III CONDUCTOR QUANTITY | 108 |
ASQB | CABLE ASSEMBLY OVERALL LENGTH | 24.000 INCHES NOMINAL |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CABLE ASSEMBLY W008 |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | 510 104 136 4TH END ALL CONDUCTORS |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | 510 104 136 5TH END ALL CONDUCTORS |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | P50-068-DDS-TG 1ST END ALL CONDUCTORS |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | P50-068-DDS-TG 2ND END ALL CONDUCTORS |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | P50-068-DDS-TG 3RD END ALL CONDUCTORS |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 18117 4TH END ALL CONDUCTORS |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 18117 5TH END ALL CONDUCTORS |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | S5746 1ST END ALL CONDUCTORS |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | S5746 2ND END ALL CONDUCTORS |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | S5746 3RD END ALL CONDUCTORS |
CXQJ | BRANCH QUANTITY | 4 |
FEAT | SPECIAL FEATURES | CABLE SPEC: M27500-28SB2U00; QTY 3 COVER S5746-P50-068-STR-BSK; QTY 108 CONTACT, AS REQUIRED INSULATION SLEEVING |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 18117 5TH END ALL CONDUCTORS |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | S5746 1ST END ALL CONDUCTORS |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | S5746 2ND END ALL CONDUCTORS |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | S5746 3RD END ALL CONDUCTORS |
CXQJ | BRANCH QUANTITY | 4 |
FEAT | SPECIAL FEATURES | CABLE SPEC: M27500-28SB2U00; QTY 3 COVER S5746-P50-068-STR-BSK; QTY 108 CONTACT, AS REQUIRED INSULATION SLEEVING |
MATT | MATERIAL | COPPER CORE CONDUCTOR ALL CONDUCTORS |
AGAV | END ITEM IDENTIFICATION | NEXT ASSEMBLY P/N 9451502; USED ON: REENTRY SYSTEM TEST SET (RSTS) |
AKRZ | TERMINATION TYPE | CONNECTOR ALL ENDS ALL CONDUCTORS |
AMQN | III CONDUCTOR QUANTITY | 108 |
ASQB | CABLE ASSEMBLY OVERALL LENGTH | 24.000 INCHES NOMINAL |
CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | CABLE ASSEMBLY W008 |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | 510 104 136 4TH END ALL CONDUCTORS |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | 510 104 136 5TH END ALL CONDUCTORS |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | P50-068-DDS-TG 1ST END ALL CONDUCTORS |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | P50-068-DDS-TG 2ND END ALL CONDUCTORS |
CXGG | TERMINAL MANUFACTURER IDENTIFYING REFERENCE NUMBER | P50-068-DDS-TG 3RD END ALL CONDUCTORS |
CXGN | TERMINAL COMMERCIAL AND GOVERNMENT ENTITY CODE | 18117 4TH END ALL CONDUCTORS |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.