Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number 213A, which is a Powersupply item from Ro Associates Inc that is listed with the NSN 6130-01-012-4720 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number 213A was specifically produced by Ro Associates Inc under the CAGE Code 24230, providing traceability. Furthermore, with the NSN 6130-01-012-4720, one can also determine that this listing falls under Federal Supply Class (FSC) 6130 Converters Electrical Non Rotating. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number 213A, and we will be in touch.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-012-4720 Item PartTypeName: POWER SUPPLY | 6130 | 010124720 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
213A | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 5.062 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 4.000 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
ANPM | INPUT PHASE | SINGLE 1ST OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 105.0 AC VOLTS MINIMUM AND 130.0 AC VOLTS MAXIMUM 2ND OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 135.0 AC VOLTS MINIMUM AND 170.0 AC VOLTS MAXIMUM 1ST OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | -12.0 DC VOLTS NOMINAL 3RD POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | -15.0 DC VOLTS NOMINAL 4TH POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 12.0 DC VOLTS NOMINAL 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 15.0 DC VOLTS NOMINAL 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST OPERATING POWER RQMT AND 1.0 KILOHERTZ MAXIMUM 1ST OPERATING POWER RQMT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND OPERATING POWER RQMT AND 1.0 KILOHERTZ MAXIMUM 2ND OPERATING POWER RQMT |
AYNH | OPERATING AMBIENT TEMP RANGE | 20.0 TO 80.0 DEG CELSIUS |
BGHX | OUTPUT CONTROL QUANTITY | 1 1ST POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 2ND POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 3RD POWER OUTPUT |
BGHX | OUTPUT CONTROL QUANTITY | 1 4TH POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 1ST POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 2ND POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 3RD POWER OUTPUT |
BGHY | OUTPUT CONTROL TYPE | FIXED VOLTAGE 4TH POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES NOMINAL 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES NOMINAL 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES NOMINAL 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 400.0 DC MILLIAMPERES NOMINAL 4TH POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 1ST POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 3RD POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | FRONT PANEL 4TH POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 1ST POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 4 4TH POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 4TH POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 1ST OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 2ND OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 2 1ST OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 2 2ND OPERATING POWER RQMT |