Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number UPGN-66-1-62-252, which is a Circuitbreaker item from Sensata Technologies Inc that is listed with the NSN 5925-01-452-9853 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number UPGN-66-1-62-252 was specifically produced by Sensata Technologies Inc under the CAGE Code 81541, providing traceability. Furthermore, with the NSN 5925-01-452-9853, one can also determine that this listing falls under Federal Supply Class (FSC) 5925 Circuit Breakers. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number UPGN-66-1-62-252, and we will be in touch.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-452-9853 Item PartTypeName: CIRCUIT BREAKER | 5925 | 014529853 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
211726 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 125.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPLM | Maximum Continuous Load Current Rating Per Pole | 2.5 AMPERES DC ALL LOCATIONS |
FREQ | Frequency In Hertz | 50.0 ALL LOCATIONS OR 60.0 ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 120.0 AC ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERVOLTAGE ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 3500.0 AC ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 150.0 ALL LOCATIONS |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
AJEC | Boss Height | 0.625 INCHES NOMINAL |
ADAT | Body Width | 1.515 INCHES MAXIMUM |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT POLE TWO |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADAQ | Body Length | 2.000 INCHES NOMINAL |
ADAU | Body Height | 2.232 INCHES MAXIMUM |
THSD | Thread Series Designator | UNC |
TTQY | Terminal Type And Quantity | 4 TAB W/SCREW |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
AAQL | Body Style | MULTIPOLE-SINGLE ACTUATOR TYPE |
MRC | Decoded Requirement | Clear Text Reply |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |