Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number 99-0368, which is a Analyzer Clinical Chemistry item from Siemens Healthcare Gmbh that is listed with the NSN 6630-01-473-3753 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number 99-0368 was specifically produced by Siemens Healthcare Gmbh under the CAGE Code 1FMH8, providing traceability. Furthermore, with the NSN 6630-01-473-3753, one can also determine that this listing falls under Federal Supply Class (FSC) 6630 Chemical Analysis Instruments. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number 99-0368, and we will be in touch.
MRC | Criteria | Characteristic |
---|---|---|
ELEC | VOLTAGE IN VOLTS | 115.0 OR 220.0 OR 100.0 |
FEAT | SPECIAL FEATURES | WHITE LIGHT DETECTOR, ACA SAMPLE CUP TEST SAMPLE/HOLDING DEVICE; NEEDLE PUMP AND VALVE ASSY TEST SAMPLE SPECIMEN DELIVERY DEVICE |
CXCY | III PART NAME ASSIGNED BY CONTROLLING AGENCY | ANALYZER CLIN CHEM PHOTOMETRIC115OR220OR100VAC WHITE LITE DETECT |
CYFV | METHOD OF ANALYSIS | PHOTOMETRIC |
AQXY | TEST TYPE FOR WHICH DESIGNED | GENERAL CHEMISTRY |
CBBL | FEATURES PROVIDED | DISCRETE PROCESSING |
CYGD | THROUGHPUT PER HOUR | 45 ASSAYS/TESTS MAXIMUM |
CYFY | ANALYSIS TEST/MEASUREMENT RANGE | 0.0 TO 2000.0 MAU |
ACZB | FREQUENCY RATING | 47.0 HERTZ NOMINAL AND 63.0 HERTZ NOMINAL |
CYFZ | TEST SAMPLE/SPECIMEN SIZE | 20.0 TO 500.0 MICROLITERS |
CYGC | REAGENT/DILUENT HOLDING DEVICE | TEST PACK |
ACDC | CURRENT TYPE | AC |
CYHM | TEST SAMPLE/SPECIMEN TYPE | SERUM, PLASMA AND URINE |