Welcome to our online Request for Quote (RFQ) service, where you can fill out and submit the form provided below to obtain tailored procurement options from our team of industry experts. You have taken interest in part number PD04WRLEEC66, which is a Counter Electronic item from Warner Robins Air Logistics Center that is listed with the NSN 6625-01-527-2770 for quick identification. Should you wish to move forward with quotation for this listing, be sure that you supply us with key details like your target pricing, quality, and delivery date. This information is what we will base presented quotes on, with responses offered shortly after the receipt and review of each form.
Note : We Will Not Share Your Information To Any Third Parties.
To ensure that customers only procure exact items of need, we present our offerings with as much relevant data as possible. For example, part number PD04WRLEEC66 was specifically produced by Warner Robins Air Logistics Center under the CAGE Code 98752, providing traceability. Furthermore, with the NSN 6625-01-527-2770, one can also determine that this listing falls under Federal Supply Class (FSC) 6625 Electrical and Electronic Properties Measuring and Testing Instruments. Alongside such details, all purchases will come delivered with any applicable qualifying certifications, furthering the reliability of our purchasing options. With this in mind, be sure to request a quote on part number PD04WRLEEC66, and we will be in touch.
MRC | Criteria | Characteristic |
---|---|---|
AMSE | VOLTAGE RATING | 110.0 VOLTS MAXIMUM |
FEAT | SPECIAL FEATURES | IAW MIL-PRF-28800;MTBF 4,000 HOURS MIN; SENSITIVITY -20DBM(BAND 1), AND .95 - 2GHZ OF -20DBM, 2-12.4 GHZ OF -25DBM, 12.4-20 GHZ OF -20 DBM, AND 20-26.5 GHZ OF -15DBM(BAND 2), AND -20DBM(BAND 3);NOMINAL INPUT IMPEDANCE 50 OHMS; MAX INPUT SIGNAL MAGNITUDE OF +7 DBM(BAND 1 AND 2); DAMAGE LEVEL SHALL HAVE A MAX. INPUT SIGNAL MAGNITUDE OF +27DBM(BAND 1) AND +45DBM CW AND +53DBM PEAK PULSED (BAND 2); AMPLITUDE DISCRIMINATION OF 15DBM(BAND 1) AND 15DBM(>50MHZ SEPERATION(BAND 2)); FREQUENCY COUNTER MUST REJECT SIGNALS OF >50MHZ OUTSIDE OF THE SPECIFIED FREQUENCY LIMITS (DOES NOT APPLY TO BAND 1 OR 3 W/FREQUENCY EXTENSION OPTION); COUNTER SHALL HAVE ABILITY TO MEASURE FM SIGNALS THAT REMAIN IN BAND ON (BAND 1)AND 20MHZ P-P ON (BAND 2) |
ABKW | OVERALL HEIGHT | 3.500 INCHES MAXIMUM |
BFHZ | MEASUREMENT TYPE | FREQUENCY |
BFJB | FREQUENCY RANGE | 0.250 TO 1.000 GIGAHERTZ F1 INPUT RATIO AND 0.950 TO 26.500 GIGAHERTZ F2 INPUT RATIO |
ABMK | OVERALL WIDTH | 16.750 INCHES MAXIMUM |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote